Download Print this page

Siemens SINAMICS G120D List Manual page 505

Hide thumbs Also See for SINAMICS G120D:

Advertisement

p20209
BI: BSW 0 switch setting I / BSW 0 sw_setting
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source of the switch setting I of instance BSW 0 of the binary changeover switch.
r20210
BO: BSW 0 output Q / BSW 0 output Q
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for output quantity Q of instance BSW 0 of the binary changeover switch.
p20211
BSW 0 run-time group / BSW 0 RTG
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
1
Description:
Setting parameter for the run-time group in which the instance BSW 0 of the binary changeover switch is to be
called.
Value:
1:
2:
3:
4:
5:
6:
9999: Do not calculate
p20212
BSW 0 run sequence / BSW 0 RunSeq
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0
Description:
Setting parameter for the run sequence of instance BSW 0 within the run-time group set in p20211.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Run-time group 1
Run-time group 2
Run-time group 3
Run-time group 4
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
7999
Parameters
List of parameters
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7250
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7250
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7250
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7250
Factory setting
580
1-505

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all