p20333
DFR 2 run sequence / DFR 2 RunSeq
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0
Description:
Setting parameter for the run-time group of instance DFR 2 within the run-time group set in p20332.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20334
BI: PDE 2 input pulse I / PDE 2 inp_pulse I
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source for the input pulse I of instance PDE 2 of the closing delay device.
p20335
PDE 2 pulse delay time in ms / PDE 2 t_del ms
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0.00
Description:
Setting parameter for pulse delay time T in milliseconds of instance PDE 2 of the closing delay device.
r20336
BO: PDE 2 output Q / PDE 2 output Q
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for output pulse Q of instance PDE 2 of the closing delay device.
p20337
PDE 2 run-time group / PDE 2 RTG
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
5
Description:
Setting parameter for the run-time group in which instance PDE 2 of the closing delay device is to be called.
Value:
5:
6:
9999: Do not calculate
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
5400000.00
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Parameters
List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7240
Factory setting
870
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7232
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7232
Factory setting
0.00
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7232
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7232
Factory setting
9999
1-529