pxxxx[0...n]
Parameter number
The parameter number is made up of a "p" or "r", followed by the parameter num-
ber and the index or bit array (optional).
Examples of representation in the parameter list:
• p...
• r...
• p0918
• p2051[0...13]
• p1001[0...n]
• r0944
• r2129.0...15
Other examples of the notation in the documentation:
• p1070[1]
• p2098[1].3
• p0795.4
The following applies to adjustable parameters:
The parameter value as delivered is specified under "Factory setting" with the rel-
evant unit in square brackets. The value can be adjusted within the range defined
by "Min" and "Max".
The term "linked parameterization" is used in cases where changes to adjustable
parameters affect the settings of other parameters.
Linked parameterization can occur, for example, as a result of the following
actions and parameters:
• Setting PROFIBUS telegram (BICO interconnections)
p0922
• Setting component lists
p0230, p0300, p0301, p0400
• Calculate and pre-assign automatically
p0340, p3900
• Restoring factory settings
p0970
The following applies to display parameters:
The fields "Min", "Max" and "Factory setting" are specified with a dash "-" and the
relevant unit in square brackets.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Adjustable parameters (read and write)
Display parameters (read-only)
Adjustable parameter 918
Adjustable parameter 2051, indices 0 to 13
Adjustable parameter 1001, indices 0 to n (n = configurable)
Display parameter 944
Display parameter 2129 with bit array from bit 0 (smallest bit)
to bit 15 (largest bit)
Adjustable parameter 1070, index 1
Adjustable parameter 2098, index 1 bit 3
Adjustable parameter 795, bit 4