r0332[0...n]
Rated motor power factor / Mot cos_phi_rated
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the rated power factor for induction motors.
For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally-calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1):
For p0309 = 0, the internally-calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency:
If p0308 is not entered, the parameter is calculated from the rating plate parameters.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0333[0...n]
Rated motor torque / Mot M_rated
Access level: 3
Can be changed: -
Units group: 7_4
Min
- [Nm]
Description:
Displays the rated motor torque.
Dependency:
IEC drives (p0100 = 0): unit Nm
NEMA drives (p0100 = 1): unit lbf ft
Note:
For induction motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328.
r0334[0...n]
Actual motor-torque constant / Mot kT act
Access level: 4
Can be changed: -
Units group: 28_1
Min
- [Nm/A]
Description:
Displays the torque constant of the synchronous motor used.
Dependency:
IEC drives (p0100 = 0): unit Nm / A
NEMA drives (p0100 = 1): unit lbf ft / A
Note:
This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 is calculated from p0305, p0307 and p0311.
p0335[0...n]
Motor cooling type / Mot cool type
Access level: 2
Can be changed: C(1, 3), T
Units group: -
Min
0
Description:
Sets the motor cooling system used.
Value:
0:
1:
2:
128:
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Non-ventilated
Forced cooling
Liquid cooling
No fan
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: p0100
Max
- [Nm]
Calculated: -
Scaling: -
Unit selection: p0100
Max
- [Nm/A]
Calculated: -
Scaling: -
Unit selection: -
Max
128
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [Nm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [Nm/A]
Data type: Integer16
Dyn. index: MDS
Func. diagram: -
Factory setting
0
1-63

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all