p0010
Drive commissioning parameter filter / Drv comm. par_filt

CU240D-2_DP

Access level: 1
CU240D-2_DP_F
Can be changed: C(1), T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0
Description:
Sets the parameter filter to commission a drive.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
Value:
0:
1:
2:
3:
4:
5:
15:
29:
30:
39:
49:
95:
Note:
The drive can only be powered up outside the drive commissioning (inverter enable). To realize this, this parameter
must be set to 0.
By setting p3900 to a value other than 0, the quick commissioning is completed, and this parameter is automatically
reset to 0.
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010
Drive commissioning parameter filter / Drv comm. par_filt
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: C(1), T
Units group: -
Min
0
Description:
Sets the parameter filter to commission a drive.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
Value:
0:
1:
2:
3:
4:
5:
15:
17:
25:
29:
30:
39:
49:
95:
Note:
The drive can only be powered up outside the drive commissioning (inverter enable). To realize this, this parameter
must be set to 0.
By setting p3900 to a value other than 0, the quick commissioning is completed, and this parameter is automatically
reset to 0.
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Ready
Quick commissioning
Power unit commissioning
Motor commissioning
Encoder commissioning
Technological application/units
Data sets
Only Siemens int
Parameter reset
Only Siemens int
Only Siemens int
Safety Integrated commissioning
Ready
Quick commissioning
Power unit commissioning
Motor commissioning
Encoder commissioning
Technological application/units
Data sets
Basic positioner commissioning
Position control commissioning
Only Siemens int
Parameter reset
Only Siemens int
Only Siemens int
Safety Integrated commissioning
Calculated: -
Scaling: -
Unit selection: -
Max
95
Calculated: -
Scaling: -
Unit selection: -
Max
95
Parameters
List of parameters
Data type: Integer16
Dyn. index: -
Func. diagram: 2800, 2818
Factory setting
1
Data type: Integer16
Dyn. index: -
Func. diagram: 2800, 2818
Factory setting
1
1-23