Parameters
List of parameters
p2098[0...1]
Inverter connector-binector converter binector output / Con/bin outp inv
Access level: 3
Can be changed: U, T
Units group: -
Min
-
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p2098[0], the signals of CI: p2099[0] are influenced.
Using p2098[1], the signals of CI: p2099[1] are influenced.
Bit field:
Bit
Signal name
00
Bit 0
01
Bit 1
02
Bit 2
03
Bit 3
04
Bit 4
05
Bit 5
06
Bit 6
07
Bit 7
08
Bit 8
09
Bit 9
10
Bit 10
11
Bit 11
12
Bit 12
13
Bit 13
14
Bit 14
15
Bit 15
Dependency:
Refer to: r2094, r2095, p2099
p2099[0...1]
CI: Connector-binector converter signal source / Con/bin S_src
Access level: 3
Can be changed: U, T
Units group: -
Min
-
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on (intercon-
nection).
Dependency:
Refer to: r2094, r2095
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p2099[0...1] together with r2094.0...15 and r2095.0...15 forms two connector-binector converters:
Connector input p2099[0] to binector output in r2094.0...15
Connector input p2099[1] to binector output in r2095.0...15
p2100[0...19]
Setting the fault number for fault response / F_no F response
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Selects the faults for which the fault response should be changed
Dependency:
The fault is selected and the required response is set under the same index.
Refer to: p2101
1-272
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
65535
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2468
Factory setting
0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Data type: U32 / Integer16
Dyn. index: -
Func. diagram: 2468
Factory setting
0
Data type: Unsigned16
Dyn. index: -
Func. diagram: 1750, 8075
Factory setting
0