p2587
EPOS jog 1 traversing distance / Jog 1 distance
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: U, T
Units group: -
Min
0 [LU]
Description:
Sets the traversing distance for incremental jog 1.
Dependency:
Refer to: p2585, p2589, p2591
Note:
Incremental jog 1 is started with BI: p2591 = 1 signal and BI: p2589 = 0/1 signal.
With BI: p2589 = 0 signal, incremental jog is interrupted.
p2588
EPOS jog 2 traversing distance / Jog 2 distance
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: U, T
Units group: -
Min
0 [LU]
Description:
Sets the traversing distance for incremental jog 2.
Dependency:
Refer to: p2586, p2590, p2591
Note:
Incremental jog 2 is started with BI: p2591 = 1 signal and BI: p2590 = 0/1 signal.
With BI: p2590 = 0 signal, incremental jogging is interrupted.
p2589
BI: EPOS jog 1 signal source / Jog 1 S_src
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for jog 1.
Dependency:
When jogging, the axis is accelerated or braked with the maximum acceleration/deceleration (p2572/p2573).
BI: p2591 = 0 signal
The axis endlessly moves with the setpoint velocity, jog 1 (p2585).
BI: p2591 = 1 signal
The axis traverses through a parameterized distance (p2585) with the setpoint velocity, jog 1 (p2587).
Refer to: p2572, p2573, p2585, p2587, p2591
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2590
BI: EPOS jog 2 signal source / Jog 2 S_src
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for jog 2.
Dependency:
When jogging, the axis is accelerated or braked with the maximum acceleration/deceleration (p2572/p2573).
BI: p2591 = 0 signal
The axis endlessly moves with the setpoint velocity, jog 2 (p2586).
BI: p2591 = 1 signal
The axis traverses through a parameterized distance (p2586) with the setpoint velocity, jog 2 (p2588).
Refer to: p2572, p2573, p2586, p2588, p2591
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
2147482647 [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
2147482647 [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3610
Factory setting
1000 [LU]
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3610
Factory setting
1000 [LU]
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3610, 3625
Factory setting
722.3
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3610, 3625
Factory setting
722.4