Download Print this page

Siemens SINAMICS G120D List Manual page 301

Hide thumbs Also See for SINAMICS G120D:

Advertisement

p2215[0...n]
CO: Technology controller fixed value 15 / Tec_ctr fix val 15
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: U, T
CU240D-2_PN
Units group: 9_1
CU240D-2_PN_F
Min
-200.00 [%]
Description:
Sets the value for fixed value 15 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2216[0...n]
Technology controller fixed value selection method / Tec_ctr FixVal sel
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
1
Description:
Sets the method to select the fixed setpoints.
Value:
1:
2:
p2220[0...n]
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2221, p2222, p2223
p2221[0...n]
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2222, p2223
p2222[0...n]
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2221, p2223
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Direct selection
Binary selection
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
150.00 [%]
Data type: Integer16
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
1
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7950
Factory setting
0
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7950
Factory setting
0
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7950
Factory setting
0
1-301

Advertisement

loading

This manual is also suitable for: