p2195[0...n]
Torque utilization switch-off delay / M_util t_off
Access level: 3
Can be changed: U, T
Units group: -
Min
0.0 [ms]
Description:
Sets the switch-off delay time for the negated signal "run-up completed".
The message "torque setpoint < p2174" (BO: r2198.10) and "torque utilization < p2194" (BO: r2199.11) are only
evaluated after the run-up and the delay time has expired.
Dependency:
Refer to: p2174, p2194
p2196[0...n]
Torque utilization scaling / M_util scal
Access level: 1
Can be changed: C(1, 3), U, T
Units group: -
Min
0.00 [%]
Description:
Sets the scaling factor for torque utilization (r0033).
r2197.0...13
CO/BO: Status word monitoring 1 / ZSW monitor 1
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the first status word for monitoring functions.
Bit field:
Bit
Signal name
00
|n_act| <= n_min p1080
01
|n_act| <= speed threshold value 2 p2155
02
|n_act| > speed threshold value 2 p2155
03
n_act >= 0
04
|n_act| >= n_set
05
|n_act| <= n_standstill p1226
06
|n_act| > n_max
07
Speed setp - act val deviation in tolerance
t_off
08
I_act >= I_threshold value p2170
09
Vdc_act <= Vdc_threshold value p2172
10
Vdc_act > Vdc_threshold value p2172
11
Output load is not present
12
|n_act| > n_max (delayed)
13
|n_act| > n_max (F07901)
Notice:
Re bit 06:
When the overspeed is reached, this bit is set and F07901 output immediately following this. The bit is canceled
again as soon as the next pulse inhibit is present.
Note:
Re bit 00:
The threshold value is set in p1080 and the hysteresis in p2150.
Re bit 01, 02:
The threshold value is set in p2155 and the hysteresis in p2140.
Re bit 03:
1 signal direction of rotation positive.
0 signal: direction of rotation negative.
The hysteresis is set in p2150.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
1000.0 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
1000.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8012
Factory setting
800.0 [ms]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
100.00 [%]
Data type: Unsigned16
Dyn. index: -
Func. diagram: 1530, 2534
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
FP
8020
8010
8010
8011
8020
8020
8010
8011
8020
8020
8020
8020
8021
-
1-295