Download Print this page

Siemens SINAMICS G120D List Manual page 220

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
p1717[0...n]
Current controller integral-action time / I_ctrl Tn
Access level: 4
Can be changed: U, T
Units group: -
Min
0.00 [ms]
Description:
Sets the integral-action time of the current controller.
Dependency:
Refer to: p1715
r1718
CO: Isq controller output / Isq_ctrl outp
Access level: 4
Can be changed: -
Units group: 5_1
Min
- [Vrms]
Description:
Displays the actual output of the Isq current controller (torque/force generating current, PI controller).
The value contains the proportional and integral components of the PI controller.
r1719
Isq controller integral component / Isq_ctrl I_comp
Access level: 4
Can be changed: -
Units group: 5_1
Min
- [Vrms]
Description:
Displays the integral component of the Isq current controller (torque/force-generating current, PI controller).
r1723
CO: Isd controller output / Isd_ctrl outp
Access level: 4
Can be changed: -
Units group: 5_1
Min
- [Vrms]
Description:
Displays the actual output of the Isd current controller (flux-generating current, PI controller).
The value contains the proportional and integral components of the PI controller.
r1724
Isd controller integral component / Isd_ctrl I_comp
Access level: 4
Can be changed: -
Units group: 5_1
Min
- [Vrms]
Description:
Displays the integral component of the Isd current controller (flux-generating current, PI controller).
1-220
Calculated: p0340 = 1,3,4
Scaling: -
Unit selection: -
Max
1000.00 [ms]
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [Vrms]
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [Vrms]
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [Vrms]
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [Vrms]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 1710, 5714, 6714,
7017
Factory setting
2.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6714
Factory setting
- [Vrms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6714
Factory setting
- [Vrms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6714
Factory setting
- [Vrms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6714
Factory setting
- [Vrms]

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all