Parameters
List of parameters
p0860
BI: Line contactor feedback signal / Line contact feedb
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the feedback signal from the line contactor.
Dependency:
Refer to: p0861, r0863
Refer to: F07300
Notice:
The line contactor monitoring is de-activated if the control signal of the particular drive object is set as the signal
source for the feedback signal of the line contactor (BI: p0860 = r0863.1).
Note:
The state of the line contactor is monitored depending on signal BO: r0863.1.
When the monitoring is activated (BI: p0860 not equal to r0863.1), fault F07300 is then also output if the contactor
is closed before it is controlled using r0863.1.
p0861
Line contactor monitoring time / LineContact t_mon
Access level: 3
Can be changed: T
Units group: -
Min
0 [ms]
Description:
Sets the monitoring time of the line contactor.
This time starts each time that the line contactor switches (r0863.1). If a feedback signal is not received from the
line contactor within the time, a message is output.
Dependency:
Refer to: p0860, r0863
Refer to: F07300
Note:
The monitoring function is disabled for the factory setting of p0860.
r0863.1
CO/BO: Drive coupling status word/control word / CoupleZSW/STW
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the status and control words of the drive coupling.
Bit field:
Bit
Signal name
01
Energize contactor
Note:
Re bit 01:
Bit 1 is used to control an external line contactor.
p0897
BI: Parking axis selection / Parking axis sel
Access level: 2
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the "parking axis" function.
Dependency:
BI: p0897 = 0 signal
The function "parking axis" is not selected.
BI: p0897 = 1 signal
The function "parking axis" is selected.
1-132
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
5000 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: U32 / Binary
Dyn. index: -
Func. diagram: -
Factory setting
863.1
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
100 [ms]
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
Data type: U32 / Binary
Dyn. index: -
Func. diagram: -
Factory setting
0
FP
-