Parameters
List of parameters
p1227
Zero speed detection monitoring time / n_standst t_monit
Access level: 3
Can be changed: U, T
Units group: -
Min
0.000 [s]
Description:
Sets the monitoring time for the standstill identification.
When braking with OFF1 or OFF3, standstill is identified after this time has expired, after the setpoint speed has
fallen below p1226 (also refer to p1145).
Dependency:
The parameter is pre-assigned depending on the size of the power unit.
Refer to: p1226
Notice:
For p1145 > 0.0 (RFG tracking) the setpoint is not equal to zero dependent on the selected value. This can there-
fore cause the monitoring time in p1227 to be exceeded. In this case, for a driven motor, the pulses are not sup-
pressed.
Note:
Standstill is identified in the following cases:
- the speed actual value falls below the speed threshold in p1226 and the time started after this in p1228 has
expired.
- the speed setpoint falls below the speed threshold in p1226 and the time started after this in p1227 has expired.
For p1227 = 300.000 s, the following applies:
Monitoring is de-activated.
For p1227 = 0.000 s, the following applies:
With OFF1 or OFF3 and a ramp-down time = 0, the pulses are immediately suppressed and the motor "coasts"
down.
Once the Control Unit has been booted up for the first time or if the factory settings have been defined accordingly,
the parameter is defined in accordance with the power unit.
p1228
Pulse suppression delay time / Pulse suppr t_del
Access level: 3
Can be changed: U, T
Units group: -
Min
0.000 [s]
Description:
Sets the delay time for pulse suppression.
After OFF1 or OFF3, the pulses are canceled, if at least one of the following conditions is fulfilled:
- the speed actual value falls below the threshold in p1226 and the time started after this in p1228 has expired.
- the speed setpoint falls below the threshold in p1226 and the time started after this in p1227 has expired.
Dependency:
Refer to: p1226, p1227
Notice:
When the motor holding brake is activated, pulse cancellation is additionally delayed by the brake closing time
(p1217).
p1230[0...n]
BI: DC braking activation / DC brake act
Access level: 2
Can be changed: U, T
Units group: -
Min
-
Description:
Sets the signal source to activate DC braking.
Dependency:
Refer to: p1231, p1232, p1233, p1234, r1239
Note:
1 signal: DC braking activated.
0 signal: DC braking de-activated.
1-182
Calculated: -
Scaling: -
Unit selection: -
Max
300.000 [s]
Calculated: -
Scaling: -
Unit selection: -
Max
299.000 [s]
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2701
Factory setting
300.000 [s]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2701
Factory setting
0.010 [s]
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7017
Factory setting
0