List of parameters
p10130
SI SDI positive input terminal (processor 2) / SI SDI pos F-DI P2
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
0
Description:
Sets the fail-safe digital input (F-DI) for the "SDI positive" function.
Value:
0:
1:
2:
3:
255:
Note:
If value = 0:
No terminal assigned, safety function always active.
If value = 255:
No terminal assigned, safety function always inactive.
F-DI: Failsafe Digital Input
SDI: Safe Direction
p10131
SI SDI negative input terminal (processor 2) / SI SDI neg F-DI P2
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
0
Description:
Sets the fail-safe digital input (F-DI) for the "SDI negative" function.
Value:
0:
1:
2:
3:
255:
Note:
If value = 0:
No terminal assigned, safety function always active.
If value = 255:
No terminal assigned, safety function always inactive.
F-DI: Failsafe Digital Input
SDI: Safe Direction
p10139
SI Safe State signal selection (processor 2) / SI Safe State Sel
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
-
Description:
Selects the individual signals that should be logically combined to create "Safe State".
Bit field:
Bit
Signal name
00
Power_removed
01
SS1_active
1-460
Statically active
F-DI 0
F-DI 1
F-DI 2
Statically inact
Statically active
F-DI 0
F-DI 1
F-DI 2
Statically inact
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Selected
Selected
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2856
Factory setting
0000 0001 bin
0 signal
Not selected
Not selected
FP
-
-