Download Print this page

Siemens SINAMICS G120D List Manual page 394

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
r8572[0...39]
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p1000
Note:
For a value = 9999999, the following applies: The read operation is still running.
r8573[0...39]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p1500
Note:
For a value = 9999999, the following applies: The read operation is still running.
r8585
Macro execution actual / Macro executed
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the macro currently being executed on the drive object.
Dependency:
Refer to: p0015, p1000, p1500, r8570, r8571, r8572, r8573
r8854
PROFINET state / PN state
CU240D-2_PN
Access level: 4
CU240D-2_PN_F
Can be changed: -
CU250D-2_PN_F
Units group: -
Min
0
Description:
State display for PROFINET.
Value:
0:
1:
2:
3:
4:
5:
6:
255:
1-394
No initialization
Fatal fault
Initialization
Send configuration
Receive configuration
Non-cyclic communication
Cyclic communications but no setpoints (stop/no clock cycle)
Cyclic communication
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
255
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
-

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all