Download Print this page

Siemens SINAMICS G120D List Manual page 539

Hide thumbs Also See for SINAMICS G120D:

Advertisement

p60022
PROFIsafe telegram selection / Ps telegram_sel
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: T
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
0
Description:
Sets the PROFIsafe telegram number.
Value:
0:
30:
900:
998:
Note:
For p9601.3 = p9801.3 = 1 (PROFIsafe enabled), the following variants exist when parameterizing PROFIsafe tele-
gram 30:
- p9611 = p9811 = 998 and p60022 = 0
- p9611 = p9811 = 998 and p60022 = 30
- p9611 = p9811 = 30 and p60022 = 30
p60022
PROFIsafe telegram selection / Ps telegram_sel
CU240D-2_DP
Access level: 3
CU240D-2_PN
Can be changed: T
Units group: -
Min
0
Description:
Sets the PROFIsafe telegram number.
Value:
0:
30:
998:
Note:
For p9601.3 = p9801.3 = 1 (PROFIsafe enabled), the following variants exist when parameterizing PROFIsafe tele-
gram 30:
- p9611 = p9811 = 998 and p60022 = 0
- p9611 = p9811 = 998 and p60022 = 30
- p9611 = p9811 = 30 and p60022 = 30
p60122
PROFIdrive SIC telegram selection / SIC telegr
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: T
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
700
Description:
Sets the telegram for the Safety Info Channel (SIC).
The SIC telegram p60122 is attached directly to the PZD telegram p0922/p2079.
Value:
700:
999:
Dependency:
Refer to: p0922, p2071, p2079
Note:
The clearance to the PZD telegram can be increased using p2071.
After changing p0922/p2079 or p2071, then p60122 must be set again.
The telegram interconnections can only be changed if p60122 and p0922 are both set to 999.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
No PROFIsafe telegram selected
PROFIsafe standard telegram 30, PZD-1/1
PROFIsafe SIEMENS telegram 900, PZD-2/2
Compatibility mode (as for firmware version < 4.6)
No PROFIsafe telegram selected
PROFIsafe standard telegram 30, PZD-1/1
Compatibility mode (as for firmware version < 4.6)
Supplementary telegram 700, PZD-0/3
Free telegram configuration with BICO
Calculated: -
Scaling: -
Unit selection: -
Max
998
Calculated: -
Scaling: -
Unit selection: -
Max
998
Calculated: -
Scaling: -
Unit selection: -
Max
999
Parameters
List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
998
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
998
Data type: Integer16
Dyn. index: -
Func. diagram: 2423
Factory setting
999
1-539