Parameters
List of parameters
Dependency:
Refer to: p2163, p2164, p2166, r2197, r2198
Refer to: F07900
Note:
When interconnecting the enable signal with r2197.7 then the stall signal is suppressed if there is no speed setpoint
- actual value deviation.
r2145[0...63]
Alarm time received in days / t_alarm recv days
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the system runtime in days when the alarm occurred.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2134, r2146
Notice:
The time comprises r2145 (days) and r2123 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2146[0...63]
Alarm time removed in days / t_alarm res days
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the system runtime in days when the alarm was cleared.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2134, r2145
Notice:
The time comprises r2146 (days) and r2125 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
p2148[0...n]
BI: RFG active / RFG active
Access level: 3
Can be changed: U, T
Units group: -
Min
-
Description:
Sets the signal source for the signal "ramp-function generator active" for the following signals/messages:
"Speed setpoint - actual value deviation within tolerance t_on" (BO: r2199.4)
"Ramp-up/ramp-down completed" (BO: r2199.5)
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The binector input is automatically interconnected to r1199.2 as a default setting.
p2149[0...n]
Monitoring configuration / Monit config
Access level: 3
Can be changed: U, T
Units group: -
Min
-
Description:
Sets the configuration for messages and monitoring functions.
Bit field:
Bit
Signal name
00
Enable alarm A07903
01
Load monitoring only in the 1st quadrant
03
n_act > p2155 own hysteresis
05
Stall monitoring for encoderless speed con-
trol
1-284
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: p0340 = 1,3,5
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8065
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8065
Factory setting
-
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 8011
Factory setting
0
Data type: Unsigned16
Dyn. index: DDS, p0180
Func. diagram: 8010, 8013
Factory setting
0000 1001 bin
0 signal
No
No
No
No
FP
8010
8013
8010
8010