p8925
PN interface configuration / PN IF config
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: U, T
CU250D-2_PN_F
Units group: -
Min
0
Description:
Setting to activate the interface configuration for the onboard PROFINET interface on the Control Unit.
p8925 is automatically set to 0 at the end of the operation.
Value:
0:
1:
2:
3:
Note:
Re p8925 = 1:
The interface configuration (p8920 and following) is activated.
Re p8925 = 2:
The interface configuration (p8920 and following) is activated and saved to non-volatile memory.
Re p8925 = 3:
Restores all memory locations for the interface configuration to the factory settings.
The factory settings for the interface configuration are loaded on activation (p8925 = 1) or at the next POWER ON.
p8929
PN remote controller number / PN rem ctrl num
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: C
CU250D-2_PN_F
Units group: -
Min
1
Description:
Sets the number of remote controllers expected for PROFINET onboard.
The "Shared Device" functionality is activated with a value = 2.
The drive is being accessed by two PROFINET controllers simultaneously:
- automation controller (SIMOTION or SIMATIC A-CPU).
- safety controller (SIMATIC F-CPU).
Value:
1:
2:
Notice:
The F CPU may only use PROFIsafe telegrams.
Note:
A change only becomes effective after POWER ON, reset or download.
r8930[0...239]
PN Name of Station active / PN Name Stat act
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_PN_F
Units group: -
Min
-
Description:
Displays the active station name for the onboard PROFINET interface on the Control Unit.
r8931[0...3]
PN IP Address of Station active / PN IP of Stat act
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_PN_F
Units group: -
Min
0
Description:
Displays the active IP address for the onboard PROFINET interface on the Control Unit.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
No function
Activate configuration
Activate and save configuration
Delete configuration
Automation or Safety
Automation and Safety
Calculated: -
Scaling: -
Unit selection: -
Max
3
Calculated: -
Scaling: -
Unit selection: -
Max
2
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
255
Parameters
List of parameters
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
1
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
1-397

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all