Download Print this page

Siemens SINAMICS G120D List Manual page 110

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
r0722.0...12
CO/BO: CU digital inputs status / CU DI status
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Displays the status of the digital inputs.
Bit field:
Bit
Signal name
00
DI 0 (X07.4)
01
DI 1 (X07.2)
02
DI 2 (X08.4)
03
DI 3 (X08.2)
04
DI 4 (X09.4)
05
DI 5 (X09.2)
11
DI 11 (X10.3) AI 0
12
DI 12 (X10.4) AI 1
Dependency:
Refer to: r0723
Note:
AI: Analog Input
DI: Digital Input
r0722.0...5
CO/BO: CU digital inputs status / CU DI status
CU250D-2_DP_F
Access level: 2
CU250D-2_PN_F
Can be changed: -
Units group: -
Min
-
Description:
Displays the status of the digital inputs.
Bit field:
Bit
Signal name
00
DI 0 (X07.4)
01
DI 1 (X07.2)
02
DI 2 (X08.4)
03
DI 3 (X08.2)
04
DI 4 (X09.4)
05
DI 5 (X09.2)
Dependency:
Refer to: r0723
Note:
DI: Digital Input
r0723.0...12
CO/BO: CU digital inputs status inverted / CU DI status inv
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Displays the inverted status of the digital inputs.
Bit field:
Bit
Signal name
00
DI 0 (X07.4)
01
DI 1 (X07.2)
02
DI 2 (X08.4)
1-110
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
High
High
High
High
High
High
High
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
High
High
High
High
High
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
High
High
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned32
Dyn. index: -
Func. diagram: 1510, 2020, 2030,
2031, 2100, 2120, 2130, 2131, 2132,
2133
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Data type: Unsigned32
Dyn. index: -
Func. diagram: 1510, 2020, 2030,
2031, 2100, 2120, 2130, 2131, 2132,
2133
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Data type: Unsigned32
Dyn. index: -
Func. diagram: 1510, 2020, 2030,
2031, 2100, 2120, 2130, 2131, 2132,
2133
Factory setting
-
0 signal
Low
Low
Low
FP
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
FP
-
-
-

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all