Parameters
List of parameters
r1791
Motor model Lh adaptation power-on frequency / MotMod Lh f_on
Access level: 4
Can be changed: -
Units group: -
Min
- [Hz]
Description:
Displays the power-on stator frequency/ primary section frequency for the Lh adaptation for the induction motor
(ASM).
r1792
Motor model Lh adaptation power-on slip / MotMod Lh fslip
Access level: 4
Can be changed: -
Units group: -
Min
- [Hz]
Description:
Displays the power-on slip frequency for the Lh adaptation for the induction motor (ASM).
p1795[0...n]
Motor model kT adaptation integral time / MotMod kT Tn
Access level: 4
Can be changed: U, T
Units group: -
Min
10 [ms]
Description:
Sets the integral time of the kT adaptation of the motor model for a permanent-magnet synchronous motor (PEM).
r1797[0...n]
Motor model kT adaptation corrective value / MotMod kT corr
Access level: 4
Can be changed: -
Units group: -
Min
- [Nm/A]
Description:
Displays the corrective value of the kT adaptation of the motor model for a permanent-magnet synchronous motor
(PEM).
Dependency:
Refer to: p0826, p1780
Note:
The display of the inactive data sets is only updated when changing over the data set.
p1800[0...n]
Pulse frequency setpoint / Pulse freq setp
Access level: 2
Can be changed: U, T
Units group: -
Min
2.000 [kHz]
Description:
Sets the pulse frequency for the converter.
This parameter is pre-set to the rated converter value when the drive is first commissioned.
Dependency:
Refer to: p0230
Note:
The maximum possible pulse frequency is also determined by the power unit being used.
When the pulse frequency is increased, depending on the particular power unit, the maximum output current can be
reduced (derating, refer to r0067).
If a sine-wave filter is parameterized as output filter (p0230 = 3), then the pulse frequency cannot be set below the
minimum value required for the filter.
For operation with output reactors, the pulse frequency is limited to 4 kHz (see p0230).
1-232
Calculated: -
Scaling: -
Unit selection: -
Max
- [Hz]
Calculated: -
Scaling: -
Unit selection: -
Max
- [Hz]
Calculated: p0340 = 1,3,4
Scaling: -
Unit selection: -
Max
10000 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
- [Nm/A]
Calculated: -
Scaling: -
Unit selection: -
Max
16.000 [kHz]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [Hz]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [Hz]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6731
Factory setting
100 [ms]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6731
Factory setting
- [Nm/A]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
4.000 [kHz]

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all