Parameters
List of parameters
Value:
0:
3:
Notice:
For p0014 = 1, the following applies:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
p2030
Field bus int protocol selection / Field bus protocol
CU240D-2_PN
Access level: 1
CU240D-2_PN_F
Can be changed: T
CU250D-2_PN_F
Units group: -
Min
0
Description:
Sets the communication protocol for the field bus interface.
Value:
0:
7:
10:
Notice:
For p0014 = 1, the following applies:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
r2032
Master control control word effective / PcCtrl STW eff
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the effective control word 1 (STW1) of the drive for the master control.
Bit field:
Bit
Signal name
00
ON/OFF1
01
OC / OFF2
02
OC / OFF3
03
Operation enable
04
Ramp-function generator enable
05
Start ramp-function generator
06
Speed setpoint enable
07
Acknowledge fault
08
Jog bit 0
09
Jog bit 1
10
Master ctrl by PLC
Notice:
The master control only influences control word 1 and speed setpoint 1. Other control words/setpoints can be trans-
ferred from another automation device.
Note:
OC: Operating condition
1-254
No protocol
PROFIBUS
No protocol
PROFINET
Ethernet/IP
Calculated: -
Scaling: -
Unit selection: -
Max
10
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
7
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
FP
-
-
-
-
-
-
-
-
3030
3030
-