p2624
EPOS traversing block sorting / Trav_block sort
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: U, T
Units group: -
Min
0
Description:
Sets the traversing blocks for sorting corresponding to their block number.
Procedure: Set p2624 = 0 --> 1.
Sorting is started and the parameters are automatically reset to zero once the operation has been completed.
Dependency:
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623
Note:
After sorting, the traversing blocks are written at the beginning of the memory in increasing sequence without any
gaps.
p2625
BI: EPOS traversing block selection bit 0 / Trav_blk sel bit 0
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the traversing block, bit 0.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2626, p2627, p2628
p2626
BI: EPOS traversing block selection bit 1 / Trav_blk sel bit 1
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the traversing block, bit 1.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2627, p2628
p2627
BI: EPOS traversing block selection bit 2 / Trav_blk sel bit 2
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the traversing block, bit 2.
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2628
p2628
BI: EPOS traversing block selection bit 3 / Trav_blk sel bit 3
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the traversing block, bit 3.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 3616
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3640
Factory setting
0