+24 V
Control Unit
SI status P1
Processor 1
r9772
r9772
CU DI status
[2804.1]
1
(X09/1)
r0722
r0722
.4
1
r9772.7
Enable STO via
terminals (P1)
1 = STO cause:
selection PROFIsafe
PROFIsafe enabled for
r9772.20
dbSI0
(p9601.2 = 0 and
[2804.1]
p9601.3 = 1) (P1)
&
0 = Select PROFIsafe
via STO
1 = STO cause: selection via
motion monitoring functions
r9772.18
[2804.2]
1 = STO release
[2819.8]
SI enable, functions integrated in the drive (p9601  0)
1 = Enable SOS/SLS
Control Unit
SI Status P2
Processor 2
r9872
r9872
CU DI status
[2804.4]
1
(X09/2)
r0722
r0722
.5
1
Enable STO via
r9872.7
terminals (P2)
1 = STO cause:
selection PROFIsafe
PROFIsafe enabled for
r9872.20
dbSI0
(p9801.2 = 0 and
[2804.4]
p9801.3 = 1) (P2)
&
0 = Select PROFIsafe
via STO
1 = STO cause: selection via
motion monitoring functions
r9872.18
[2804.2]
1 = STO release
[2819.8]
SI enable, functions integrated in the drive (p9801  0)
1 = Enable SOS/SLS
1
2
Safety Integrated Basic Functions
STO (Safe Torque Off)
1 = STO selected
on P1
r9772.0
1 = STOP A [2802.8]
.17
1
&
1
[2802.2]
[2804.4]
&
&
1 = Safety
commissioning mode
[2800.3]
<2>
1
p9501.0
1 = STO
selected on P2
r9872.0
1 = STOP A [2802.8]
.17
1
&
1
[2802.2]
[2804.4]
&
&
1 = Safety commissioning mode
[2800.3]
1
p9301.0
3
4
A01699
SI FCP Timer
"Shutdown
0.00 ... 9000.00 [h]
paths must
p9659 (8.00)
be tested"
SI status P1+P2
<1>
T
0
r9773
r9773
.31
1 = Shutdown
Timer for forced
paths must
checking
be tested
procedure
0 = Request pulse suppression P1
SI F-DI_chg tol P1
0.00 ... 2000.00 [ms]
p9650 (500.00)
F01611
T
0
(P1)
=1
F30611
(P2)
SI F-DI_chg tol P2
0.00 ... 2000000.00 [μs]
p9850 (500000.00)
Monitoring for simultaneous occurrence
0 = Request pulse suppression P2
1 = "STO active" for
&
sequence control
[2802.1] DIAG_L
[2802.1] DIAG_U
<1>
Switch-on delay starts when the "request pulse suppression P1" is withdrawn.
<2>
Redundant functions in the Processor 1 (P1) and Processor 2 (P2).
Transistors inhibited for a "0" signal.
<3>
PM-IF: Power Module Interface
STO: Safe Torque Off
5
6
fp_2810_97_57.vsd
12.12.2012
Power Module
SI status P1
[2804.2]
r9772
r9772
.1
1 = STO active on
Control Unit
1
+5 V
Shutdown
path from P1
Upper IGBT
0 = STO_P1
bridge halve
<3>
Safe pulse
Gating unit
suppression
+5 V
Shutdown
path from P2
Lower IGBT
0 = STO_P2
bridge halve
<3>
Gating unit
7
Function diagram
SINAMICS G120D
V4.6
U
V
M
W
8
- 2810 -