p2662
BI: EPOS adjustment value valid feedback signal / Adj val valid FS
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the feedback signal "adjustment value valid".
BI: p2662 = 1 signal
The adjustment value received via CI: p2660 is valid.
BI: p2662 = 0 signal
The adjustment value received via CI: p2660 is not valid.
Dependency:
Refer to: r2526, p2660
p2663
BI: EPOS clamping active feedback signal / Clamping active FS
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the feedback signal "clamping active for travel to fixed stop".
BI: p2663 = 1 signal
Clamping is active
BI: p2663 = 0 signal
Clamping is not active.
Dependency:
Refer to: r2526
Note:
The feedback signal from "terminals active" is, for the factory setting, dependent on the signal BO: r2526.8 (termi-
nals active when moving to a fixed stop).
r2665
CO: EPOS position setpoint / s_set
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: -
Units group: -
Min
- [LU]
Description:
Displays the actual absolute position setpoint.
Dependency:
Refer to: p2530
Note:
As standard, the following BICO interconnection is established: CI: p2530 = r2665
r2666
CO: EPOS velocity setpoint / v_set
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: -
Units group: -
Min
- [1000 LU/min]
Description:
Displays the actual velocity setpoint.
Dependency:
Refer to: p2531
Note:
As standard, the following BICO interconnection is established: CI: p2531 = r2666
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
- [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
- [1000 LU/min]
Parameters
List of parameters
Data type: U32 / Binary
Dyn. index: -
Func. diagram: -
Factory setting
2526.9
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616
Factory setting
2526.8
Data type: Integer32
Dyn. index: -
Func. diagram: 3635
Factory setting
- [LU]
Data type: Integer32
Dyn. index: -
Func. diagram: 3635
Factory setting
- [1000 LU/min]