Download Print this page

Siemens SINAMICS G120D List Manual page 348

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
p2614
BI: EPOS search for reference reversing cam plus / Rev plus
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2613
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
p2615
EPOS maximum number of traversing blocks / Trav_block qty max
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: C(17)
Units group: -
Min
1
Description:
Sets the maximum number of traversing blocks that are available.
Dependency:
Refer to: p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
p2616[0...n]
EPOS traversing block block number / Trav_blk, blkNo.
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: U, T
Units group: -
Min
-1
Description:
Sets a block number.
-1: Invalid block number. These blocks are not taken into account.
0 ... 15: Valid block number.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
p2617[0...n]
EPOS traversing block position / Trav_block pos
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: U, T
Units group: -
Min
-2147482648 [LU]
Description:
Sets the target position for the traversing block.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Note:
The target position is approached in either relative or absolute terms depending on p2623.
1-348
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
16
Calculated: -
Scaling: -
Unit selection: -
Max
15
Calculated: -
Scaling: -
Unit selection: -
Max
2147482647 [LU]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612
Factory setting
1
Data type: Unsigned8
Dyn. index: -
Func. diagram: 3616
Factory setting
16
Data type: Integer16
Dyn. index: p2615
Func. diagram: 3616
Factory setting
-1
Data type: Integer32
Dyn. index: p2615
Func. diagram: 3616
Factory setting
0 [LU]