p9931[0...129]
System logbook module selection / SYSLOG mod select
Access level: 4
Can be changed: U, T
Units group: -
Min
0000 hex
Description:
Only for service purposes.
p9932
Save system logbook EEPROM / SYSLOG EEPROM save
Access level: 4
Can be changed: U, T
Units group: -
Min
0
Description:
Only for service purposes.
r9935.0
BO: POWER ON delay signal / POWER ON t_delay
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Display and binector output for a delay after POWER ON.
After power-on, binector output r9935.0 is set with the start of the first sampling time and is again reset after approx.
100 ms.
Bit field:
Bit
Signal name
00
POWER ON delay signal
r9975[0...7]
System utilization measured / Sys util meas
Access level: 4
Can be changed: -
Units group: -
Min
- [%]
Description:
Displays the measured system utilization.
The higher the value displayed, the higher the system utilization.
Index:
[0] = Computing time utilization (min)
[1] = Computing time utilization (averaged)
[2] = Computing time utilization (max)
[3] = Largest total utilization (min)
[4] = Largest total utilization (averaged)
[5] = Largest total utilization (max)
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: r9976
Refer to: F01054, F01205
Note:
Re index 3 ... 5:
The total utilizations are determined using all sampling times used. The largest total utilizations are mapped here.
The sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
High
Calculated: -
Scaling: -
Unit selection: -
Max
- [%]
Parameters
List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0000 hex
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
Low
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [%]
FP
-
1-449