From speed signals [8010.8]
From speed signals
From speed signals [8011.8]
From speed signals [8011.8]
From speed signals [8012.5]
<1> n_act = smoothed speed actual value r2169 [8010.2].
1
2
Internal control/status words
Status word, monitoring functions 3
PROFIdrive-Bit
Bit No.
Status word, monitoring functions 3 (r2199)
0
1 = |n_act| < speed threshold value 3 (p2161)
[8010.8]
1
1 = f or n comparison value reached or exceeded (p2141)
Reserved
2
3
Reserved
4
1 = Speed setpoint - actual value deviation within tolerance t_on
1 = Ramp-up/ramp-down completed
5
0 = Ramp-function generator active
Reserved
6
Reserved
7
8
Reserved
9
Reserved
10
Reserved
1 = Torque utilization < torque threshold value 2 (p2194)
11
Reserved
12
13
Reserved
14
Reserved
Reserved
15
3
4
r2199.0
<1>
r2199.1
r2199.4
r2199.5
r2199.11
5
6
Function diagram
fp_2537_97_57.vsd
SINAMICS G120D
12.12.2012
V4.6
ZSW monitor 3
r2199
r2199
[8012.1]
7
8
- 2537 -