Parameters
List of parameters
p0404[0...n]
Encoder configuration effective / Enc_config eff
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: C(4)
Units group: -
Min
-
Description:
Settings for the basic encoder properties.
Bit field:
Bit
Signal name
00
Linear encoder
01
Absolute encoder
02
Multiturn encoder
03
Track A/B sq-wave
09
SSI encoder
12
Equidistant zero mark
13
Irregular zero mark
14
Distance-coded zero mark
21
Voltage level 24 V
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400
should be carefully observed when removing write protection.
Note:
ZM: Zero mark
Re bit 12 (equidistant zero mark):
The zero marks occur at regular intervals (e.g. rotary encoder with 1 zero mark per revolution or linear encoder with
constant zero mark distance).
The bit activates monitoring of the zero mark distance (p0424/p0425, linear/rotary) or in the case of the linear
encoder with 1 zero mark and p0424 = 0 zero mark monitoring is activated.
Re bit 13 (irregular zero mark):
The zero marks occur at irregular intervals (e.g. a linear scale with only 1 zero mark in the traversing range). The
zero mark distance is not monitored.
Re bit 14 (distance-coded zero mark):
The distance (clearance) between two or several consecutive zero marks allows the absolute position to be calcu-
lated.
p0405[0...n]
Square-wave encoder track A/B / Sq-wave enc A/B
Access level: 3
Can be changed: C(4)
Units group: -
Min
-
Description:
Settings for the track A/B in a square-wave encoder.
For square-wave encoders, p0404.3 must also be 1.
Bit field:
Bit
Signal name
00
Signal
01
Level
02
Track monitoring
03
Zero pulse
04
Switching threshold
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
Re bit 00:
For G120D, only "Bipolar" is supported.
1-76
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Bipolar
TTL
A/B <> -A/B
Same as A/B track
High
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned32
Dyn. index: EDS
Func. diagram: 4010, 4704
Factory setting
0000 0000 0010 0000 0000 0000
0000 0000 bin
0 signal
No
No
No
No
No
No
No
No
No
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: 4704
Factory setting
0000 1001 bin
0 signal
Unipolar
HTL
None
24 V unipolar
Low
FP
-
-
-
-
-
-
-
-
-
FP
-
-
-
-
-