Parameters
List of parameters
p20177
PDF 1 run sequence / PDF 1 RunSeq
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0
Description:
Setting parameter for the run sequence of instance PDF 1 within the run-time group set in p20176.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20178[0...1]
BI: PST 0 inputs / PST 0 inputs
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source for input pulse I and the reset input R of instance PST 0 of the pulse extension element.
Index:
[0] = Input pulse I
[1] = Reset input R
p20179
PST 0 pulse duration in ms / PST 0 pulse_dur ms
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0.00
Description:
Setting parameter for pulse duration T in milliseconds of instance PST 0 of the pulse extension element.
r20180
BO: PST 0 output Q / PST 0 output Q
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for output pulse Q of instance PST 0 of the pulse extension element.
p20181
PST 0 run-time group / PST 0 RTG
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
5
Description:
Setting parameter for the run-time group in which the instance PST 0 of the pulse extension element is to be called.
Value:
5:
6:
9999: Do not calculate
1-498
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
5400000.00
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7233
Factory setting
470
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 7234
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7234
Factory setting
0.00
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7234
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7234
Factory setting
9999