Parameters
Symbol
Meaning
Parameter name [Unit]
Monitoring parameter with
rxxxx[y..z]
unit [Unit] and index range
[y..z] or data set [C/D]
Parameter name
Setting parameter with min/
from ... to [Unit]
max value and unit [Unit] data
pxxxx[C/D] (Def)
set [C/D] and factory setting
(Def) *)
Information on parameters, binectors, connectors
Meaning
Symbol
Parameter name (up to 18 characters)
Parameter name
[dimension unit]
[Unit]
"r" = monitoring parameter. These parameters are read-only
"xxxx" stands for the parameter number
rxxxx[y] or
"[y]" specifies the applicable index, "[y...z]" specifies the index range
rxxxx[y...z] or
".ww" specifies the bit number (e.g. 0...15).
rxxxx[y].ww or
rxxxx.ww
"p" = setting parameter. These parameters can be changed.
"xxxx" stands for the parameter number,
pxxxx[y] or
"[y]" specifies the applicable index, "[y...z]" specifies the index range ".ww" specifies
pxxxx[y...z] or
the bit number (e.g. 0...15).
pxxxx[y].ww or
pxxxx.ww
Value range.
from ... to
Parameter number (xxxx) with Index number [y] and bit number .ww.
(xxxx[y].ww)
Factory setting.
(Def)
Factory setting with bit number as prefix.
(Def.w)
Diagram references for setting parameters that occur a multiple number of times.
[aaaa.b]
[Function diagram number, signal path]
*)
For some parameters the value for the factory setting is calculated during commissioning for they are dependent on Power Module and motor (see Section 1.1.1 "Calculated").
1
2
Explanations for the function diagrams
Explanation of the symbols (Part 1)
Connectors
Symbol
Meaning
Parameter name
Connector input CI with
index range [y..z]
pxxxx[y..z]
or data set [C/D]
(Def)
and factory setting (Def) *)
Parameter name [Unit]
Connector output CO with
unit [Unit] and with index
rxxxx[y..z]
range [y..z]
Connectors/binectors
Symbol
Meaning
Parameter name
rxxxx
Connector/binector output CO/BO
rxxxx
3
4
Binectors
Symbol
Meaning
Parameter name
Binector input BI with with
index range [y..z] or data set
pxxxx[y..z]
[C/D] and factory setting.bit
(Def.y)
number (Def)
Parameter name
Binector output BO
rxxxx
Pre-assigned connectors
Symbol
Meaning
Parameter name
Setting parameter with min/
from ... to [Unit]
max value and unit [Unit] data
pxxxx[D] (Def)
set [D] and factory setting
(Def)
Cross references between diagrams
Symbol
Meaning
Signal path
The function diagrams are sub-divided into signal
paths 1...8 in order to facilitate orientation.
Text
Text = Unique signal designation
[aaaa.b]
aaaa = Signal to target diagram aaa
b
= Signal to signal path b
Text
Text = Unique signal designation
[cccc.d]
cccc = Signal from source diagram cccc
d
=Signal from signal path d
To "function diagram name" [aaaa.b] = binectors.
Cross references for control bits
Symbol
Meaning
pxxxx= Original parameter of signal
pxxxx
aaaa = Signa from source diagram aaaa
[aaaa.b]
b
= Signal from signal path b
5
6
Function diagram
fp_1020_97_61.vsd
SINAMICS G120D
12.12.2012
V4.6
Data sets
Symbol
Meaning
pxxxx[C]
Parameter belongs to the
Command Data Set (CDS).
Parameter belongs to the Drive
pxxxx[D]
Data Set (DDS).
7
8
- 1020 -

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all