[0] = Limited
[1] = Unlimited
r1538
CO: Upper effective torque limit / M_max upper eff
Access level: 2
Can be changed: -
Units group: 7_1
Min
- [Nm]
Description:
Displays the currently effective upper torque limit.
Note:
The effective upper torque limit is reduced with respect to the selected upper torque limit p1520, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
This may be the case for rotating measurements (see p1960).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
r1539
CO: Lower effective torque limit / M_max lower eff
Access level: 2
Can be changed: -
Units group: 7_1
Min
- [Nm]
Description:
Displays the currently effective lower torque limit.
Note:
The effective lower torque limit is reduced with respect to the selected lower torque limit p1521, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
This may be the case for rotating measurements (see p1960).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
p1545[0...n]
BI: Activates travel to a fixed stop / TfS activation
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source to activate/de-activate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1545[0...n]
BI: Activates travel to a fixed stop / TfS activation
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to activate/de-activate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
When traveling to fixed stop, the fault F07900 "motor blocked" is suppressed.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 1610, 1700, 5610,
5650, 6060, 6640
Factory setting
- [Nm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 1610, 1700, 5610,
5650, 6060, 6640
Factory setting
- [Nm]
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 2520, 3617, 8012
Factory setting
0
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 2520, 8012
Factory setting
2683.14
1-213