Parameters
List of parameters
Notice:
It is not possible to re-parameterize the acknowledge mode of a fault in the following cases:
- if there is no existing fault number.
- the message type is not "fault" (F).
Note:
Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has
been resolved.
The acknowledge mode can only be changed for faults with the appropriate identification.
Example:
F12345 and acknowledge mode = IMMEDIATELY (POWER ON)
--> The acknowledge mode can be changed from IMMEDIATELY to POWER ON.
p2128[0...15]
Selecting fault/alarm code for trigger / Message trigger
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Selects faults or alarms which can be used as trigger.
Dependency:
Refer to: r2129
r2129.0...15
CO/BO: Trigger word for faults and alarms / Trigger word
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Trigger signal for the selected faults and alarms
Bit field:
Bit
Signal name
00
Trigger signal p2128[0]
01
Trigger signal p2128[1]
02
Trigger signal p2128[2]
03
Trigger signal p2128[3]
04
Trigger signal p2128[4]
05
Trigger signal p2128[5]
06
Trigger signal p2128[6]
07
Trigger signal p2128[7]
08
Trigger signal p2128[8]
09
Trigger signal p2128[9]
10
Trigger signal p2128[10]
11
Trigger signal p2128[11]
12
Trigger signal p2128[12]
13
Trigger signal p2128[13]
14
Trigger signal p2128[14]
15
Trigger signal p2128[15]
Dependency:
If one of the faults or alarms selected in p2128[n] occurs, then the particular bit of this binector output is set.
Refer to: p2128
Note:
CO: r2129 = 0 --> None of the selected messages has occurred.
CO: r2129 > 0 --> At least one of the selected messages has occurred.
1-280
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: 1750, 8070
Factory setting
0
Data type: Unsigned16
Dyn. index: -
Func. diagram: 1530, 8070
Factory setting
-
0 signal
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-