Download Print this page

Siemens SINAMICS G120D List Manual page 342

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2591
BI: EPOS jogging incremental / Jog incr
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for jogging incremental.
Dependency:
Refer to: p2585, p2586, p2587, p2588, p2589, p2590
p2593
CI: EPOS LU/revolution LU/mm / LU/rev LU/mm
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency:
Refer to: p0404, r2524, p2594
Note:
The signal value is used to convert the length unit to the speed or velocity setpoint.
p2594[0...2]
CI: EPOS Maximum velocity externally limited / v_Max ext lim
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the externally limited maximum velocity.
Index:
[0] = Setpoint limit absolute
[1] = Setpoint limiting positive
[2] = Setpoint limiting negative
Dependency:
Refer to: r2524, p2571, p2593
Warning:
In order that the externally limited velocity can be effective for the EPOS operating modes, connector input p2593
must be correctly interconnected.
p2595
BI: EPOS referencing start / Ref start
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to start the "search for reference" or "flying referencing".
BI: p2595 = 0/1 signal
Referencing is started.
BI: p2595 = 1/0 signal
Referencing is interrupted.
Dependency:
Refer to: p2597, p2598, p2599, r2684
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
1-342
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3610
Factory setting
722.5
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 3630
Factory setting
2524[0]
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 3630
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612, 3625, 3614
Factory setting
0

Advertisement

loading

This manual is also suitable for: