Parameters
List of parameters
12
De-activate rotor resistance Rr measure-
ment
14
De-activate valve interlocking time mea-
surement
15
Determine only stator resistance, valve volt-
age fault, dead time
16
Short motor identification (lower quality)
17
Measurement without control parameter cal-
culation
Dependency:
Refer to: r3925
Note:
The parameter is a copy of p1909.
r3928[0...n]
Rotating measurement configuration / Rot meas config
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Successfully completed component of the last rotating measurement carried out.
Bit field:
Bit
Signal name
01
Saturation characteristic identification
02
Moment of inertia identification
03
Re-calculates the speed controller parame-
ters
04
Speed controller optimization (vibration test) Yes
05
q leakage inductance ident. (for current con-
troller adaptation)
11
Do not change the controller parameters
during the measurement
12
Measurement shortened
13
After measurement: direct transition into
operation
Dependency:
Refer to: r3925
Note:
The parameter is a copy of p1959.
r3929[0...n]
Motor data identification modulated voltage generation / MotID U_gen mod
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Configuration of voltage generation for the various MotID sections in the case of the most recent successful MotID.
Bit field:
Bit
Signal name
00
Wobble U_generate to determine dead-time
correction
01
Wobble U_generate to determine stator
resistance
02
Wobble U_generation to determine rotor
time constant
03
Wobble U_generation to determine leakage
inductance
04
Wobble U_generation to determine dynamic
leakage inductance
05
Wobble U_generation to determine magne-
tizing inductance
08
Alternating U_generate to determine dead-
time correction
1-378
Yes
Yes
Yes
Yes
Yes
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
No
No
No
No
No
Data type: Unsigned16
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
Data type: Unsigned32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
-