Parameters
List of parameters
r0087
CO: Actual power factor / Cos phi act
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the actual active power factor.
This value refers to the electrical power of the basic fundamental signals at the output terminals of the converter.
r0089[0...2]
Actual phase voltage / U_phase act val
Access level: 4
Can be changed: -
Units group: 5_3
Min
- [V]
Description:
Displays the actual phase voltage.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Note:
The values are determined from the transistor power-on duration.
r0094
CO: Transformation angle / Transformat_angle
Access level: 3
Can be changed: -
Units group: -
Min
- [°]
Description:
Displays the transformation angle.
Dependency:
Refer to: r1778
Note:
The transformation angle corresponds to the electrical commutation angle.
p0100
IEC/NEMA mot stds / IEC/NEMA mot stds
Access level: 1
Can be changed: C(1)
Units group: -
Min
0
Description:
Defines whether the motor and drive converter power settings (e.g. rated motor power, p0307) are expressed in
[kW] or [hp].
Depending on the selection, the rated motor frequency (p0310) is either set to 50 Hz or 60 Hz.
For p0100 = 0, 2, the following applies: The power factor (p0308) should be parameterized.
For p0100 = 1, the following applies: The efficiency (p0309) should be parameterized.
Value:
0:
1:
2:
Dependency:
If p0100 is changed, all of the rated motor parameters are reset. Only then are possible unit changeovers made.
The units of all motor parameters are changed that are involved in the selection of IEC or NEMA (e.g. r0206, p0307,
r0333, r0334, p0341, p0344, r1969).
Refer to: r0206, p0210, p0300, p0304, p0305, p0307, p0308, p0309, p0310, p0311, p0314, p0320, p0322, p0323,
p0335, r0337, p1800
Note:
The parameter value is not reset when the factory setting is restored (p0010 = 30, p0970).
1-44
IEC-Motor (50 Hz, SI units)
NEMA motor (60 Hz, US units)
NEMA motor (60 Hz, SI units)
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: p2001
Unit selection: p0505
Max
- [V]
Calculated: -
Scaling: p2005
Unit selection: -
Max
- [°]
Calculated: -
Scaling: -
Unit selection: -
Max
2
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6719
Factory setting
- [V]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [°]
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all