Example:
Change over command data set
CDS0 --> CDS1
BI: p0810 = "0"
BI: p0810 = "1"
CDS0 selected
CDS1 selected
r0836.0 = 0
r0836.0 = 1
t
CDS0 effective
CDS1 effective
r0050.0 = 0
r0050.0 = 1
Note
Data sets can only be applied
and cleared when p0010 = 15
is set.
1
2
Data sets
Command Data Sets (CDS)
t
Source CDS
p0809[0] (0)
t
CDS select bit 0
p0810
(722.3)
CDS select bit 1
p0811
CDS3
(0)
CDS2
CDS1
CDS0
3
4
Target CDS
p0809[1] (1)
Start copy process
p0809[2] (0)
CDS count
2 ... 4
p0170 (2)
5
6
fp_8560_97_51.vsd
12.12.2012
CDS selected
r0836
r0836
.0
r0836.1
CDS effective
r0050
r0050
.0
r0050.1