p20277
LVM 1 interval limit L / LVM 1 limit L
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-340.28235E36
Description:
Setting parameter for the interval limit L of instance LVM 1 of the double-sided limiter.
p20278
LVM 1 hyst HY / LVM 1 hyst HY
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-340.28235E36
Description:
Setting parameter for hysteresis HY of instance LVM 1 of the double-sided limiter.
r20279
BO: LVM 1 input quantity above interval QU / LVM 1 X above QU
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter of instance LVM 1 of the double-sided limiter that input quantity X was at least once X > M + L
and X is >= M + L - HY.
r20280
BO: LVM 1 input quantity within interval QM / LVM 1 X within QM
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter of instance LVM 1 of the double-sided limiter that the input quantity X lies within the interval.
r20281
BO: LVM 1 input quantity below interval QL / LVM 1 X below QL
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter of instance LVM 1 of the double-sided limiter that input quantity X was at least once X < M - L
and X is <= M - L + HY.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7270
Factory setting
0.0000
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7270
Factory setting
0.0000
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7270
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7270
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7270
Factory setting
-