p0124[0...n]
CU detection via LED / CU detection LED
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Identification of the Control Unit using an LED.
Note:
While p0124 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate Control Unit.
p0133[0...n]
Motor configuration / Motor config
Access level: 2
Can be changed: C(1, 3)
Units group: -
Min
-
Description:
Configuration of the motor when commissioning the motor.
Bit field:
Bit
Signal name
00
Motor connection type
01
Motor 87 Hz operation
Dependency:
For standard induction motors (p0301 > 10000), bit 0 is automatically preassigned the connection type of the
selected data set.
For p0100 > 0 (60 Hz rated motor frequency), it is not possible to select bit 1.
Refer to: p0304, p0305, p1082
Note:
Re bit 0:
When changing the bits, the rated motor voltage p0304 and the rated motor current p0305 are automatically con-
verted to the selected connection type (star or delta connection).
Re bit 1:
Operation with 87 Hz is only possible in the delta connection type. When selected, the maximum speed p1082 is
automatically preassigned for a maximum output frequency of 87 Hz.
p0170
Number of Command Data Sets (CDS) / CDS count
Access level: 2
Can be changed: C(15)
Units group: -
Min
2
Description:
Sets the number of Command Data Sets (CDS).
Dependency:
Refer to: p0010, r3996
Notice:
When the data sets are created, short-term communication interruptions may occur.
Note:
It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
p0180
Number of Drive Data Sets (DDS) / DDS count
Access level: 3
Can be changed: C(15)
Units group: -
Min
1
Description:
Sets the number of Drive Data Sets (DDS).
Dependency:
Refer to: p0010, r3996
Notice:
When the data sets are created, short-term communication interruptions may occur.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Delta
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
4
Calculated: -
Scaling: -
Unit selection: -
Max
4
Parameters
List of parameters
Data type: Unsigned8
Dyn. index: PDS
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: MDS
Func. diagram: -
Factory setting
0000 bin
0 signal
Star
No
Data type: Unsigned8
Dyn. index: -
Func. diagram: 8560
Factory setting
2
Data type: Unsigned8
Dyn. index: -
Func. diagram: 8565
Factory setting
1