Download Print this page

Siemens SINAMICS G120D List Manual page 74

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
r0395[0...n]
Actual stator resistance / R_stator act
Access level: 3
Can be changed: -
Units group: -
Min
- [ohm]
Description:
Displays the actual stator resistance (phase value).
The parameter value also contains the temperature-independent cable resistance.
Dependency:
In the case of induction motors the parameter is also affected by the motor temperature model.
Refer to: p0350, p0352, p0620
Note:
In each case, only the stator resistance of the active Motor Data Set is included with the stator temperature of the
thermal motor model.
r0396[0...n]
Actual rotor resistance / R_rotor act
Access level: 3
Can be changed: -
Units group: -
Min
- [ohm]
Description:
Displays the actual rotor resistance (phase value).
The parameter is affected by the motor temperature model.
Dependency:
Refer to: p0354, p0620
Note:
In each case, only the rotor resistance of the active Motor Data Set is included with the rotor temperature of the
thermal motor model.
This parameter is not used for synchronous motors (p0300 = 2xx).
p0397[0...n]
Angle magnetic decoupling maximum angle / Magn decpl max_ang
Access level: 4
Can be changed: U, T
Units group: -
Min
0.0 [°]
Description:
Maximum angle when calculating the polynomial function to decouple the magnetic flux axes for permanent-magnet
synchronous motors (see p0398, p0399).
p0400[0...n]
Encoder type selection / Enc_typ sel
CU240D-2_DP
Access level: 1
CU240D-2_DP_F
Can be changed: C(1, 4)
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0
Description:
Selects the encoder from the list of encoder types supported.
Value:
0:
3001: 1024 HTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3007: 2048 HTL A/B
9999: User-defined
1-74
No encoder
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: -
Scaling: -
Unit selection: -
Max
- [ohm]
Calculated: p0340 = 1,2
Scaling: -
Unit selection: -
Max
90.0 [°]
Calculated: -
Scaling: -
Unit selection: -
Max
9999
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: 6730
Factory setting
- [ohm]
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
90.0 [°]
Data type: Integer16
Dyn. index: EDS
Func. diagram: 1580, 4704
Factory setting
0

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all