r0026
CO: DC link voltage smoothed / Vdc smooth
Access level: 2
Can be changed: -
Units group: -
Min
- [V]
Description:
Displays the smoothed actual value of the DC link voltage.
Dependency:
Refer to: r0070
Notice:
When measuring a DC link voltage < 200 V, for the Power Module (e.g. PM240) a valid measured value is not sup-
plied. In this case, when an external 24 V power supply is connected, a value of approx. 24 V is displayed in the dis-
play parameter.
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The DC link voltage is available smoothed (r0026) and unsmoothed (r0070).
r0026 sets itself to the lower value of the pulsating DC link voltage.
r0027
CO: Absolute actual current smoothed / I_act abs val smth
Access level: 2
Can be changed: -
Units group: -
Min
- [Arms]
Description:
Displays the smoothed absolute actual current value.
Dependency:
Refer to: r0068
Notice:
This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the
unsmoothed value should be used.
Note:
Smoothing time constant = 300 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
r0028
Modulation depth smoothed / Mod_depth smth
Access level: 4
Can be changed: -
Units group: -
Min
- [%]
Description:
Displays the smoothed actual value of the modulation depth.
Dependency:
Refer to: r0074
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The modulation depth is available smoothed (r0028) and unsmoothed (r0074).
r0029
Current actual value field-generating smoothed / Id_act smooth
Access level: 4
Can be changed: -
Units group: -
Min
- [Arms]
Description:
Displays the smoothed field-generating actual current.
Dependency:
Refer to: r0076
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: p2001
Unit selection: -
Max
- [V]
Calculated: -
Scaling: p2002
Unit selection: -
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: -
Max
- [%]
Calculated: -
Scaling: p2002
Unit selection: -
Max
- [Arms]
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6799
Factory setting
- [V]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5730, 6799, 8850,
8950
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5730, 6799, 8950
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6799
Factory setting
- [Arms]
1-27