List of parameters
Danger:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
p1524[0...n]
CO: Torque limit upper/motoring scaling / M_max up/mot scal
Access level: 3
Can be changed: U, T
Units group: -
Min
-2000.0 [%]
Description:
Sets the scaling for the upper torque limit or the torque limit when motoring.
Dependency:
p1400.4 = 0: upper/lower
p1400.4 = 1: motoring / regenerating
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
p1525[0...n]
CO: Torque limit lower scaling / M_max lower scal
Access level: 3
Can be changed: U, T
Units group: -
Min
-2000.0 [%]
Description:
Sets the scaling for the lower torque limit.
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
This parameter can be freely interconnected.
The value has the meaning stated above if it is interconnected from connector input p1528.
r1526
CO: Torque limit upper without offset / M_max up w/o offs
Access level: 3
Can be changed: -
Units group: 7_1
Min
- [Nm]
Description:
Displays the upper torque limit of all torque limits without offset.
Dependency:
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
r1527
CO: Torque limit lower without offset / M_max low w/o offs
Access level: 3
Can be changed: -
Units group: 7_1
Min
- [Nm]
Description:
Displays the lower torque limit of all torque limits without offset.
Dependency:
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
1-210
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
2000.0 [%]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
2000.0 [%]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 5620, 5630
Factory setting
100.0 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6630
Factory setting
100.0 [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6060, 6630, 6640
Factory setting
- [Nm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6060, 6630, 6640
Factory setting
- [Nm]