Download Print this page

Siemens SINAMICS G120D List Manual page 347

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Dependency:
Refer to: p2595, p2597, p2604, p2607, p2608, p2610
Refer to: F07459
p2610
EPOS search for ref. tol. bandwidth for distance to zero mark / Tol_band to ZM
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: U, T
Units group: -
Min
0 [LU]
Description:
Sets the tolerance bandwidth for the distance to the zero mark
The zero mark is evaluated within the maximum distance between the reference cam and zero mark (p2609) minus
the tolerance bandwidth for the distance to the zero mark (p2610).
Dependency:
Refer to: p2609
p2611
EPOS search for reference approach velocity reference point / v_appr ref_pt
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: U, T
Units group: -
Min
1 [1000 LU/min]
Description:
Sets the approach velocity after detecting the zero mark to approach the reference point.
Dependency:
Refer to: p2595, p2597, p2604, p2607, p2609, p2610
Note:
When traversing to the reference point, the velocity override is not effective.
p2612
BI: EPOS search for reference reference cam / Ref_cam
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the reference cam.
Dependency:
Refer to: p2607
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p2613
BI: EPOS search for reference reversing cam minus / Rev minus
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2614
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
2147482647 [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
40000000 [1000 LU/min]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3612
Factory setting
2147482647 [LU]
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3612
Factory setting
300 [1000 LU/min]
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612
Factory setting
1
1-347

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all