p0581
Measuring probe edge / MT edge
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Sets the edge to evaluate the measuring probe signal for speed actual value measurement.
0: 0/1 edge
1: 1/0 edge
Dependency:
Refer to: p0580
p0582
Measuring probe pulses per revolution / MT pulses per rev
Access level: 3
Can be changed: U, T
Units group: -
Min
1
Description:
Sets the number of pulses per revolution (e.g. for disks with holes).
p0583
Measuring probe maximum measuring time / MT t_meas max
Access level: 3
Can be changed: U, T
Units group: -
Min
0.040 [s]
Description:
Sets the maximum measuring time for the measuring probe.
If a new pulse is not received before the maximum measuring time has expired, then the speed actual value in
r0586 is set to zero. This timer is re-started with the next pulse.
Dependency:
Refer to: r0586
p0585
Measuring probe gear factor / Probe gear factor
Access level: 3
Can be changed: U, T
Units group: -
Min
0.00000
Description:
Sets the BERO gear factor.
The measured speed is multiplied by the BERO gear factor and is displayed in r0586.
r0586
CO: Measuring probe speed actual value / MT n_act
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the speed actual value measured using the BERO.
Dependency:
Refer to: p0580, p0583
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
12
Calculated: -
Scaling: -
Unit selection: -
Max
10.000 [s]
Calculated: -
Scaling: -
Unit selection: -
Max
1000.00000
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Parameters
List of parameters
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
1
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
10.000 [s]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
1.00000
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [rpm]