Download Print this page

Siemens SINAMICS G120D List Manual page 39

Hide thumbs Also See for SINAMICS G120D:

Advertisement

r0064
CO: Speed controller system deviation / n_ctrl system dev
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the actual system deviation of the speed controller.
r0065
Slip frequency / f_Slip
Access level: 3
Can be changed: -
Units group: 2_1
Min
- [Hz]
Description:
Displays the slip frequency for induction motors (ASM).
r0066
CO: Output frequency / f_outp
Access level: 3
Can be changed: -
Units group: 2_1
Min
- [Hz]
Description:
Display and connector output for the output frequency of the power unit.
Dependency:
Refer to: r0024
Note:
The output frequency is available smoothed (r0024) and unsmoothed (r0066).
For vector control and operation with encoder (p0400 > 0), the following applies:
The parameter value corresponds to the actual encoder speed.
r0067
CO: Output current maximum / I_outp max
Access level: 3
Can be changed: -
Units group: 6_2
Min
- [Arms]
Description:
Displays the maximum output current of the power unit.
Dependency:
The maximum output current is determined by the parameterized current limit and the motor and converter thermal
protection.
Refer to: p0290, p0640
r0068[0...1]
CO: Absolute current actual value / I_act abs val
Access level: 3
Can be changed: -
Units group: 6_2
Min
- [Arms]
Description:
Displays actual absolute current.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [Hz]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [Hz]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5040, 6040
Factory setting
- [rpm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 1710, 6310, 6727,
6730, 6732
Factory setting
- [Hz]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 1690, 6310, 6730,
6731, 6799
Factory setting
- [Hz]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6300, 6640, 6724
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 1690, 6714, 6799,
7017, 8014, 8017, 8018
Factory setting
- [Arms]
1-39