r1169
CO: Speed controller speed setpoints 1 and 2 / n_ctrl n_set 1/2
Access level: 4
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the speed setpoint after the addition of the speed setpoint 1 (p1155) and speed setpoint 2 (p1160).
Dependency:
Refer to: p1155, p1160
Note:
The value is only correctly displayed at r0899.2 = 1 (operation enabled).
r1170
CO: Speed controller setpoint sum / n_ctrl setp sum
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the speed setpoint after selecting the ramp-function generator and adding the speed setpoint 1 (p1155)
and speed setpoint 2 (p1160).
Dependency:
Refer to: r1150, p1155, p1160
r1197
Fixed speed setpoint number actual / n_set_fixed No act
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the number of the selected fixed speed/velocity setpoint.
Dependency:
Refer to: p1020, p1021, p1022, p1023
Note:
If a fixed speed setpoint has not been selected (p1020 ... p1023 = 0, r1197 = 0), then r1024 = 0 (setpoint = 0).
r1198.0...15
CO/BO: Control word setpoint channel / STW setpoint chan
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the control word for the setpoint channel.
Bit field:
Bit
Signal name
00
Fixed setpoint bit 0
01
Fixed setpoint bit 1
02
Fixed setpoint bit 2
03
Fixed setpoint bit 3
05
Inhibit negative direction
06
Inhibit positive direction
11
Setpoint inversion
13
Motorized potentiometer raise
14
Motorized potentiometer lower
15
Bypass ramp-function generator
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3080
Factory setting
- [rpm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 1550, 1590, 1690,
1700, 1750, 3080, 5020, 6030
Factory setting
- [rpm]
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3010
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 1530, 2505
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
FP
3010
3010
3010
3010
3040
3040
3040
3020
3020
3060,
3070
1-173