1 ms
t_System relative
0 ... 4294967295 [ms]
p0969 (0)
32 bit counter,
free running
III
[8065.1]
Operating time
Faults ackn DO
p3981
POWER ON
STW fault/alarm
p2103 ... p2105
r2138
r2138
.7
[2546.7]
STW fault/alarm
p2106
r2138
r2138
.13
[2546.7]
STW fault/alarm
p2107
r2138
r2138
.14
[2546.7]
STW fault/alarm
p2108, p3110 ... p3112
r2138
r2138
.15
[2546.7]
<1>
This fault is overwritten when "more recent" faults occur.
<2>
The buffer parameters are cyclically updated in the background (refer to the status signal in r2139).
1
2
Faults and warnings
Fault buffer
Actual fault code
r2131
<2>
Fault code
Fault value
Fault times
r0949[0] [I32]
r0945[0]
Fault
1
r2133[0] [Float]
r0949[1] [I32]
r0945[1]
Fault 2
r2133[1] [Float]
Actual
fault case
r0949[7] [I32]
r0945[7]
Fault 8
r2133[7] [Float]
Faults
Acknowledging
r0949[8] [I32]
r0945[8]
Fault
1
r2133[8] [Float]
r0949[9] [I32]
Fault 2
r0945[9]
r2133[9] [Float]
1. Acknow-
ledged
fault case
r0949[15] [I32]
Fault 8
r0945[15]
r2133[15] [Float]
r0949[56] [I32]
Fault
1
r0945[56]
r2133[56] [Float]
r0949[57] [I32]
r0945[57]
Fault 2
r2133[57] [Float]
7. Acknow-
ledged
fault case
[oldest]
r0949[63] [I32]
Fault 8
r0945[63]
r2133[63] [Float]
3
4
LED "RDY" [= red for fault]
0 = "No fault present"
Fault time
Fault time
"received"
"removed"
r0948[0] [ms]
r2109[0] [ms]
r2130[0] [d]
r2136[0] [d]
r0948[1] [ms]
r2109[1] [ms]
r2130[1] [d]
r2136[1] [d]
RESET
r0948[7] [ms]
r2109[7] [ms]
<1>
r2130[7] [d]
r2136[7] [d]
r0948[8] [ms]
r2109[8] [ms]
r2130[8] [d]
r2136[8] [d]
r0948[9] [ms]
r2109[9] [ms]
r2130[9] [d]
r2136[9] [d]
r0948[15] [ms]
r2109[15] [ms]
r2130[15] [d]
r2136[15] [d]
r0948[56] [ms]
r2109[56] [ms]
r2130[56] [d]
r2136[56] [d]
r0948[57] [ms]
r2109[57] [ms]
r2130[57] [d]
r2136[57] [d]
r0948[63] [ms]
r2109[63] [ms]
r2130[63] [d]
r2136[63] [d]
ZSW fault/alarm 1
5
6
fp_8060_97_51.vsd
12.12.2012
Counter
16 bit
Fault cases qty
Fault case
III
appears
RESET
Delete fault buffer
p0952 = 0:
Fault buffer is deleted/
r0945 = 0
cleared
r0948 = 0
r0949 = 0
r2109 = 0
1
r2130 = 0
r2133 = 0
r2136 = 0
16 bit counter, free
running
Fault appears
Fault disappears
1
III
Fault case acknowl.
RESET
POWER ON
Fault buffer change [8065.6]
Fault responses to the sequence control
r2139
r2139
.3
[2548.2]
7
Function diagram
SINAMICS G120D
V4.6
0 ... 65535
p0952 (0)
Automatic
Fault buff change
r0944
8
- 8060 -