[6722.6]
[6730.5][6731.5]
[6722.3]
[6714.8]
[6310.8]
[6730.5][6731.5]
[6060.7]
[6220.8][6320.8]
[6220.8][6320.8]
<1>
Only for U/f control
1
2
Internal control/status words
Status word, closed-loop control
Bit No.
Status word closed-loop control (r0056)
0
1 = Initialization completed
1 = De-magnetization completed
1
1 = Pulses enabled
2
3
1 = Soft starting available
4
1 = Magnetization completed
5
1 = Starting boost active
1 = Acceleration voltage active
6
7
1 = Frequency, negative
8
1 = Field weakening active
9
1 = Voltage limit active
1 = Slip limiting active
10
1 = Frequency limit active
11
12
1 = Current limiting controller, voltage output active
13
1 = Current/torque limiting active
14
1 = Vdc_max controller active
1 = Vdc_min controller active
15
3
4
ZSW cl-loop ctrl
r0056
r0056
r0056.0
r0056.1
r0056.2
<1>
r0056.3
r0056.4
r0056.5
<1>
r0056.6
r0056.7
r0056.8
r0056.9
<1>
r0056.10
r0056.11
<1>
r0056.12
[8012.5]
r0056.13
<1>
r0056.14
[6031.6][6710.2]
r0056.15
[6710.2]
5
6
Function diagram
fp_2526_97_63.vsd
SINAMICS G120D
12.12.2012
V4.6
7
8
- 2526 -