Parameters
List of parameters
Dependency:
Binector inputs p2625, p2626, p2627 and p2628 are used to select one of the maximum of 16 traversing blocks.
Refer to: p2625, p2626, p2627
p2631
BI: EPOS activate traversing task (0 -> 1) / Trav_task act
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for "activating traversing task".
BI: p2631 = 0/1 signal
The traversing task, selected using BI: p2625 ... p2630, is started.
Dependency:
Refer to: p2625, p2626, p2627, p2628, p2640, p2641
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
To start a traversing block, the axis must be referenced (r2684.11 = 1).
The status signal r2684.12 = 0/1 signal is used for acknowledgement.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
p2632
EPOS external block change evaluation / Ext BlckChg eval
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
0
Description:
Sets the mode to evaluate "external block change".
Value:
0:
1:
Dependency:
Refer to: p2623, p2633, r2677, r2678
Note:
In the mode "external block change via measuring probe (p2632 = 0), the following applies:
When starting a traversing block with the block change enable CONTINUE_EXTERNAL,
CONTINUE_EXTERNAL_WAIT and CONTINUE_EXTERNAL_ALARM an activated "flying referencing" is inter-
rupted. After ending the block, "flying referencing" must be re-activated via BI: p2595 = 0/1 signal.
p2633
BI: EPOS external block change (0 -> 1) / Ext BlckChg (0->1)
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for "external block change".
BI: p2633 = 0/1 signal
Dependency:
The evaluation of the signal is only active p2632 = 1.
Refer to: p2623, p2632, p2640, p2641, r2677, r2678
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
A 0/1 edge initiates a flying block change in the subsequent traversing block.
When the external block change is identified, the actual position is saved in r2678.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
1-352
External block change via the measuring probe
External block change via BI: p2633
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3616, 3625
Factory setting
0
Data type: Integer16
Dyn. index: -
Func. diagram: 3615, 3616
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3615
Factory setting
0