Download Print this page

Siemens SINAMICS G120D List Manual page 176

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
r1204.0...13
CO/BO: Flying restart U/f control status / FlyRest Uf st
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the status for checking and monitoring flying restart states in the U/f control mode.
Bit field:
Bit
Signal name
00
Current impressed
01
No current flow
02
Voltage input
03
Voltage reduced
04
Start ramp-function generator
05
Wait for execution
06
Slope filter act
07
Positive gradient
08
Current < thresh
09
Current minimum
10
Search in the positive direction
11
Stop after positive direction
12
Stop after negative direction
13
No result
r1205.0...15
CO/BO: Flying restart vector control status / FlyRest vector st
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the status for checking and monitoring flying restart states in the vector control mode.
Bit field:
Bit
Signal name
00
Speed adaptation circuit record angle
01
Speed adaptation circuit set gain to 0
02
Isd channel enable
03
Speed control switched out
04
Quadrature arm switched in
05
Special transformation active
06
Speed adaptation circuit set I comp to 0
07
Current control on
08
Isd_set = 0 A
09
Frequency held
10
Search in the positive direction
11
Search Started
12
Current impressed
13
Search interrupted
14
Speed adaptation circuit deviation = 0
15
Speed control activated
Note:
Re bit 00 ... 09:
Used to control internal sequences during the flying restart.
Depending on the motor type (p0300), the number of active bits differs.
Re bits 10 ... 15:
Are used to monitor the flying restart sequence.
1-176
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all