p4684[0...n]
Zero mark monitoring tolerance window alarm threshold negative / ZM tol A_thr neg
Access level: 3
Can be changed: C(4)
Units group: -
Min
-100001
Description:
Sets the negative tolerance window in encoder pulses for limit 2 for the zero mark monitoring.
If the zero mark deviation is higher than the tolerance set in p4681 and p4682 and fault F3x131 is re-parameterized
to alarm (A) or no message (N), the accumulator p4688 is compared with this parameter and, if applicable, alarm
A3x422 is output for 5 seconds.
Dependency:
Refer to: p0437, p4683, p4688
Refer to: F31131, A31422
Note:
Zero mark monitoring is activated by setting p0437.2 = 1 (position actual value correction).
For a set value = -100001, the negated value of p4683 is effective.
p4685[0...n]
Speed actual value mean value generation / n_act mean val
Access level: 3
Can be changed: C(4)
Units group: -
Min
0
Description:
Sets the number of current controller clock cycles for mean value generation of the speed actual value.
Note:
Value = 0, 1: No mean value generation.
Higher values also mean higher dead times for the speed actual value.
p4686[0...n]
Zero mark minimum length / ZM min length
Access level: 3
Can be changed: C(4)
Units group: -
Min
0
Description:
Sets the minimum length for the zero mark.
Dependency:
Refer to: p0425, p0437
Note:
The value for the minimum length of the zero mark must be set less than p0425.
The parameter is activated using p0437.1 = 1 (zero mark edge detection).
p4688[0...2]
CO: Zero mark monitoring differential pulse count / ZM diff_pulse qty
Access level: 3
Can be changed: T
Units group: -
Min
-2147483648
Description:
Displays the number of differential pulses for the zero mark monitoring that have accumulated.
If fault F3x131 is re-parameterized to alarm (A) or no message (N), the encoder pulses which have not been cor-
rected are added to the accumulator (p4688).
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p4681, p4682, p4683, p4684
Note:
The display can only be reset to zero.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
0
Calculated: -
Scaling: -
Unit selection: -
Max
20
Calculated: -
Scaling: -
Unit selection: -
Max
10
Calculated: -
Scaling: -
Unit selection: -
Max
2147483647
Parameters
List of parameters
Data type: Integer32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
-100001
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
1
Data type: Integer32
Dyn. index: -
Func. diagram: -
Factory setting
0
1-385

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all