Parameters
List of parameters
p9650
SI F-DI changeover tolerance time (processor 1) / SI F-DI_chg tol P1
Access level: 3
Can be changed: C(95)
Units group: -
Min
0.00 [ms]
Description:
Sets the tolerance time for the changeover of the failsafe digital input for STO on processor 1.
An F-DI changeover is not effective simultaneously due to the different runtimes in the two monitoring channels.
After an F-DI changeover, dynamic data is not subject to a crosswise data comparison during this tolerance time.
Dependency:
Refer to: p9850
Note:
For a crosswise data comparison between p9650 and p9850, a difference of one Safety monitoring clock cycle is
tolerated.
The parameterized time is rounded internally to an integer multiple of the monitoring clock cycle.
F-DI: Failsafe Digital Input
p9651
SI STO debounce time (processor 1) / SI STO t_debou P1
Access level: 3
Can be changed: C(95)
Units group: -
Min
0.00 [ms]
Description:
Sets the debounce time for the failsafe digital inputs used to control the "STO" function.
The debounce time is rounded to whole milliseconds.
Note:
The debounce time is rounded to whole milliseconds. It specifies the maximum duration of a fault pulse at the fail-
safe digital inputs with no reaction/influence on the selection or deselection of the Safety Basic Functions.
Example:
Debounce time = 1 ms: Fault pulses of 1 ms are filtered; only pulses longer than 2 ms are processed.
Debounce time = 3 ms: Fault pulses of 3 ms are filtered; only pulses longer than 4 ms are processed.
p9659
SI forced checking procedure timer / SI FCP Timer
Access level: 3
Can be changed: C(95)
Units group: -
Min
0.00 [h]
Description:
Sets the time interval for carrying out the forced checking procedure and testing the Safety shutdown paths.
Within the parameterized time, STO must have been de-selected at least once. The monitoring time is reset each
time that STO is de-selected.
Dependency:
Refer to: A01699
Note:
STO: Safe Torque Off
r9660
SI forced checking procedure remaining time / SI frc chk remain
Access level: 3
Can be changed: -
Units group: -
Min
- [h]
Description:
Displays the time remaining before dynamization and testing of the safety shutdown paths (forced checking proce-
dure).
Dependency:
Refer to: A01699
1-428
Calculated: -
Scaling: -
Unit selection: -
Max
2000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
100.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
9000.00 [h]
Calculated: -
Scaling: -
Unit selection: -
Max
- [h]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2810
Factory setting
500.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
1.00 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2810
Factory setting
8.00 [h]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [h]

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all